The SAW-48 Automated Nucleic Acid Extraction Station (hereinafter referred to as “SAW-48”), produced by Jiangsu Bioperfectus Technologies Co., Ltd., is an in vitro diagnostic medical device that integrates advanced mechanical, electronic, and software technologies. The SAW-48 combines sample loading, nucleic acid purification, and PCR setup functions into a single piece of equipment. The typical execution time is less than 45 minutes for 1–48 samples.
Based on proven magnetic separation technology, the SAW-48 offers high-throughput automation combined with high performance, promoting increased laboratory productivity to meet varying demands. With non-contact dispensing of samples, reagents, and PCR reagents, the system is safe and simple for operators, while also saving time and costs for the laboratory.
Integrated station
“Walk-away” system from the primary sample tube to the PCR-ready tube, including sample loading, nucleic acid purification, and PCR setup.
Customizable workflow
Pre-programmed protocols adaptable to different needs.
High speed
Processing of 1–48 samples with the entire process completed in 45 minutes.
User-friendly design
Visual interface with functions displayed in real-time within the software.
Better contamination control
UV light, HEPA filter, and electrostatic filter help prevent aerosols in the internal environment. Scientific zoning, a pipetting device with a leak-proof design, and filtered tips increase the level of prevention against cross-contamination.
| Dimensions (L × W × H) | 740 x 650 x 730(mm) |
| Weight | 50kg |
| Sample capacity | 1-48 |
| Cooling control 4–15 °C for reagent station and 4–8 °C for PCR preparation station. |
|
| Contamination control Nucleic acid extraction and solution dispensing operations are strictly performed in separate areas. An integrated medical purifier consists of two UV disinfection modules with timers, two HEPA filters, and a high-efficiency, high-voltage electrostatic filter for particle capture, equipped with four fans. |
|
| Voltage | 100-240 V AC |
| Frequency | 50-60 Hz |
| Rated power | 420 VA |
|
Sampling Function |
|
| Compatible sample tubes |
Sample tubes and centrifuge tubes, such as 1.5 mL, 5 mL tubes and tubes with 16 mm diameter. |
| Sample types |
Plasma, serum, whole blood, swab, urine, etc. |
| Extraction Function | |
| Magnetic bead recovery efficiency ≥ 98% |
|
| Processing volume | 20-1,000 μL |
| Mixing mode Oscillatory mixing with multiple modes and speeds (>20 levels) |
|
| Compatible kit Bioperfectus magnetic bead-based nucleic acid extraction kits |
|
| Heating temperature | Lysis heating: room temperature to 120°C |
| Elution heating: room temperature to 120°C | |
|
Pipetting Function |
|
| Sample loading channels | |
| Reagent tubes 1.5 mL, 2 mL, 5 mL EP tubes; 0.2 mL PCR tubes |
|
| Piston pump dispensing volume | 1-250 μL |
| Positioning accuracy ±0.1 mm in X-Y-Z axes |
NMPA, CE, FDA Listed